Vector VTR-13-012 dry air steriliser — forced-air dry-heat oven for sterilising glassware, tools, and temperature-tolerant laboratory equipment without moisture.

VTR-13-012

Dry Air Steriliser

Forced-air dry heat · programmable sterilisation · glassware & lab tools

Overview

The Vector VTR-13-012 Dry Air Steriliser is a laboratory forced-air dry-heat oven for sterilising glassware, metal tools, and temperature-tolerant accessories — without steam, moisture, or pressure-vessel infrastructure.

Circulated hot air holds the chamber at programmed sterilisation temperature and duration so wrapped and unwrapped loads reach repeatable thermal exposure — suited to busy materials, cement, and general QC laboratories that need reliable oven sterilisation beside furnaces and climatic equipment.

Vector configures the VTR-13-012 for internal SOPs and typical dry-heat sterilisation practice referenced to ISO 17025 traceability requirements on the same line as sample prep, balances, and analysis instruments.

At a glance

  • VTR-13-012 — dry air steriliser / laboratory oven
  • Forced-air — uniform chamber temperature
  • Programmable — setpoint, hold time, and alarms
  • Stainless interior — adjustable shelving
  • Moisture-free — dry heat for glass and metal loads
  • CE marked laboratory equipment

Standards & conformity

Browse the standards library

Supports laboratory dry-heat sterilisation and drying workflows aligned with your referenced method and internal quality system. Supplied as CE-marked equipment with Vector support for temperature programme setup and load layout.

Vector VTR-13-012 dry air steriliser — laboratory forced-air dry-heat oven

Applications

Dry-heat sterilisation and controlled drying for laboratories that must keep glassware, tools, and accessories ready without autoclave moisture.

Glassware & labware

Beakers, flasks, and metal accessories — repeatable thermal sterilisation before sensitive chemical or physical testing.

Cement & materials QC

Drying and heat treatment of tools and containers used on mortar, aggregate, and powder lines.

Sample prep

Conditioning of temperature-tolerant items before weighing, sieving, or crushing workflows.

General drying

Moisture removal on specimens and apparatus where steam sterilisation is unsuitable.

Education & R&D

Teaching and method development for dry-heat exposure profiles beside muffle furnaces and climatic chambers.

Key features

Uniform dry heat, visible chamber access, and traceable programmes for everyday laboratory sterilisation.

Air

Forced circulation

Fan-assisted airflow for even temperature across shelves — reduce cold spots in loaded chambers.

Dry

Moisture-free heat

No steam cycle — protect moisture-sensitive glass and metal items from autoclave condensation.

Program

Setpoint & timer

Store typical sterilisation and drying temperatures with defined hold duration per SOP.

Interior

Stainless chamber

Corrosion-resistant lining with adjustable shelves for trays, baskets, and bulk glassware.

Safety

Protected operation

Insulated enclosure with overtemperature protection for continuous laboratory use.

CE

Laboratory equipment

CE-marked unit for plant laboratories, commercial testing, and university research.

Vector VTR-13-012 dry air steriliser — chamber interior and shelving

Chamber & dry heat

Loads are placed on adjustable shelves inside an insulated chamber. Forced-air circulation raises temperature to the sterilisation setpoint; hold time completes the thermal exposure before the chamber cools for safe unloading.

  • Even exposure — circulated air supports uniform heating across typical glassware layouts.
  • Flexible shelving — configure height for trays, baskets, and tall vessels.
  • No moisture cycle — dry heat only, for items unsuitable for steam sterilisation.
Vector VTR-13-012 dry air steriliser — control panel and temperature programming

Control & operation

The control interface centralises temperature entry, timer settings, and status indication. Operators recall typical sterilisation and drying profiles, monitor approach to setpoint, and unload when the cycle completes.

  • Stored programmes — recall typical sterilisation and drying temperatures.
  • Alarms & limits — early warning on deviation from target temperature.
  • Vector support — programme setup, shelving layout, and SOP alignment.
Vector VTR-13-012 dry air steriliser — brochure cover

Downloads

Product brochure for the Vector VTR-13-012 dry air steriliser — chamber volume, temperature range, forced-air circulation, and typical laboratory sterilisation applications.

Brochure (PDF)

Vector dry air steriliser

Technical overview

Product code
VTR-13-012
Function
Dry-heat sterilisation and controlled drying
Principle
Forced-air circulation oven
Control
Programmable temperature and hold time
Chamber
Insulated cabinet with stainless interior and adjustable shelving
Typical applications
Glassware sterilisation, lab tools, drying, cement and materials QC support